Home > products > Communications Security Equipment >
High Precise Telecom Equipment / Telecommunication Devices Corrosion Resistance YH6006

High Precise Telecom Equipment / Telecommunication Devices Corrosion Resistance YH6006

telecommunication network equipment

network communication equipment

Place of Origin:

CHINA

Brand Name:

YUHUI

Certification:

ISO9001

Model Number:

Communications Security Equipment Multi functional Accept ODM and OEM From China Factory Flexible Size

Contact Us
Request A Quote
Product Details
Material:
Cold Rolled Steel Plate Or Alloy
OEM:
Accept
Test:
Accept
Sample:
Accept
Odm:
Accept
Advantage:
Communications Security Equipment Multi Functional Accept ODM And OEM From China Factory Flexible Size
Payment & Shipping Terms
Minimum Order Quantity
10
Price
negotiable
Packaging Details
cartons and PU box
Delivery Time
10 work days
Payment Terms
L/C, T/T, Western Union, MoneyGram
Supply Ability
10000 per week
Product Description

Communications Security Equipment Multi functional Accept ODM and OEM From China Factory Flexible Size YH6006

The communications equipment installation engineering involves more professional than communication line engineering, and each has its own characteristics. Including the program-controlled exchange professional, professional transmission equipment, professional mobile communications, communications power professional, professional satellite communications, digital data, professional microwave communications.
Communication equipment professional and communication line professional demarcation is on the main distribution frame (MDF) and optical distribution frame (ODF). The outside of the distribution frame belongs to the line, and the inner side belongs to the equipment professional construction. It can be seen that the communication equipment profession is less affected by the environment than the circuit profession.
Communications companies must ensure that the entire communications network and the entire network are uninterrupted. Therefore, the construction of communication equipment, especially capacity expansion and expansion operations, in order to ensure the safety of communications equipment in operation, in order to ensure the safety of construction workers must require construction workers to strictly comply with the technical requirements for the safe production of communications equipment installation, strictly abide by the mandatory Sexual standards, strict compliance with safety practices.
Section 1 General Safety Requirements
First, the general safety requirements
1. When the equipment is out of the box, the signs on the packing box should be taken care of and must not be inverted. Special tools should be used when opening the box. It is strictly forbidden to beat the box with a hammer. After opening the box, it is necessary to promptly clean the board, tin, foam and other debris. Rain, snow, and wet weather must not be opened outdoors.
2. Do not damage the floor and other equipment while moving the equipment inside the machine room.
3. The work and equipment used in the construction work shall be in good condition and shall not be sick.
4. The construction site should be equipped with fire-fighting equipment. It is forbidden to store flammable and explosive materials in the equipment room. It is forbidden to smoke or drink in the engine room.
5. When working in the equipment room where the equipment has been operated, the construction work area should be demarcated. Workers must not touch the transport equipment; they must not turn off the power switch at will.
6. The power wiring of multi-purpose sockets, electric irons, hand drills, hammers and other tools should be well insulated; it is forbidden to hang the AC power cables on communication equipment.
7. Temporary power sources for construction should be equipped with a leakage protector and marked with voltage and capacity. When using the original power outlet in the equipment room, you must first measure the voltage and verify the power switch capacity.
8. No tools or equipment shall be placed on the iron frame, channel, rack, or ladder. When placing tools and equipment on a high stool, people must remove them when they leave. When moving a high stool, check and clean the tools and equipment on the high stool first.
9. Work at heights should use insulated ladders or bar stools. It is forbidden to step on iron frames, racks and cables. It is forbidden to climb the patch panel bracket; it is forbidden to step on the terminal board and the spring row.
10. Electricity-related work must use well-insulated tools and be operated by professionals. When operating in charged equipment, front cabinets, and branch cabinets, operators should remove metal jewelry such as watches, rings, and necklaces. Wells to take effective measures to prevent screws, gaskets, copper and other metal materials fall caused by short circuit.
11. When operating at the top of the equipment, protective measures shall be taken for the equipment to be operated. Metal objects such as tools and screws are prohibited from falling into the cabinet.
12. Important processes should be handled by skilled personnel. The construction unit with the workers or supervisors, engineering quality inspectors shall supervise and inspect at the construction site.
13. When the system is cutover, the cutover scheme and data backup should be done and an emergency plan should be prepared at the same time.
14. Every day before leaving the site, the site should be cleaned and the power supply should be cut off. Check the power supply and other unsafe factors to confirm that there are no safety hazards.

Send your inquiry directly to us